Thermal House Model
This page documents the functionality of the thermal house available in SIMONA.
Behaviour
This house model represents the thermal behaviour of a building. It represents a simple shoebox with thermal capacity and transmission losses for its heating demand. As well the hot water demand (tap water) based on the number of inhabitants and the housing type on hourly basis is considered. The house can optionally be equipped with a Cylindrical Thermal Storage as thermal storage. Both are connected by the Thermal Grid Model.
The thermal house provides two different energy demands. The required demand indicates that the inner temperature of the house is below the lower temperature boundary and thus, requires mandatory heating. An additional demand indicates the amount of energy necessary to reach the target temperature. Additional demand not necessarily requires to be covered but could, e.g. for flexibility purposes.
There are different operating modes, depending on whether the heat source is em-controlled or not.
Behaviour without EM control
If the heat source of this building is not under Energy Management control, the internal temperature of the house should remain between the target temperature and lower temperature boundary. If the temperature falls below the lower temperature limit, the available energy from the storage is used first. If the storage is empty, the heat pump will first heat the house up to the target temperature and then refill the storage. As the storage is initialised as empty, the heat source will start charging the storage first. Whenever the heat source is in operation (e.g. to charge the storage), it will continue to operate until the house has reached the target temperature again.
Behaviour under EM control
When Energy Management is applied to the heat source of this building, the thermal behaviour should be basically the same as without EM control, so internal temperature of the house should remain between the target temperature and the lower temperature limit.
However, for flexibility usage, the energy management system can turn on the heat source whenever the thermal house has additional demand. Same for the thermal storage. When the heat source is EM controlled, the thermal storage will only be recharged when the flexibility strategy allows. E.g. when there is surplus energy from PV plant. If the power target of the EM changes (e.g. due to a change in the weather), the heat source can be turned off when charging the thermal storage, but not if it is being used to heat the house and this heating cannot be replaced by the thermal storage.
Physical Model
Thermal Calculations
With formula of the thermal flux for the heat losses by
where
\(\dot{Q}\) = Thermal Flux in \(W\)
\(\lambda\) = Thermal Conductivity in \(\frac{W}{m \cdot K}\)
A = Surface in \(m^2\)
T = Inner and Outer Temperature in \(K\)
and of temperature deviation when heating by
where
\(\Delta{T}\) = Temperature difference \(T_{inner}\) and \(T_{outer}\) in \(K\)
\(\Delta{Q}\) = Transferred heat in \(J\)
m = Mass of the medium in \(kg\)
c = Specific Heat Capacity of the medium in \(\frac{J}{kg \cdot K}\)
One derives
This can be transformed to
By defining
this will be
By integration one receives
By replacing with the house parameters of thermal losses
and thermal capacity
we \(k_1\) and \(k_2\) transforms to
Inner Temperature Calculation
Thus, the inner temperature can be calculated by
where
\(T_1\) = New Temperature in \(K\)
\(T_0\) = Last Temperature in \(K\)
Calculate next threshold
Since for \(t \rightarrow \infty\)
will be
This allows to determine which boundary will be reached next. The exact time step can be calculated by
where
\(T_1\) = New Temperature in \(K\)
\(T_0\) = Last Temperature in \(K\)
References:
Meschede [Meschede.2005]
Becker and Jodl [Becker.1991]
Attributes, Units and Remarks
Please refer to PowerSystemDataModel - Thermal House Model for Attributes and Units used in this Model.